Emergency Diesel Generator Set
  • Emergency Diesel Generator SetEmergency Diesel Generator Set

Emergency Diesel Generator Set

Kecheng is an experienced manufacturer of emergency diesel generator sets, who can offer a full range of emergency power generation equipment from 20 to 2000kW. This product is specially designed for sudden power outages. It can be quickly started up and provide stable power, ensuring the continuity of power supply in key places such as hospitals, factories and commercial facilities.

China Kecheng’s emergency diesel generator sets are a reliable choice for equipping critical facilities with emergency backup power. This series of products has a power coverage ranging from 20 to 2,000 kilowatts. They can quickly start up after a power outage and provide stable power to important loads in a timely manner. The core of the unit is equipped with engines from well-known brands such as Yuchai, Weichai or Cummins, combined with efficient generators and intelligent control systems, ensuring reliable operation and easy maintenance. The product can be customized according to the specific load requirements on site, such as specific power, voltage or starting method, etc. It has passed quality certifications such as ISO9001 and CE, and the core components are guaranteed for two years or 5,000 hours. Whether it is medical emergency rescue, industrial production, municipal facilities or commercial operations, this emergency generator set can provide solid power support in the event of sudden power outages, effectively reducing the losses and risks caused by power outages.

Emergency Diesel Generator Set

Application scenarios

Emergency Diesel Generator Set

1. Medical system

• Applicable scenarios: Hospital ICU wards, operating rooms, emergency centers, blood cold storage, medical equipment (ventilators, dialysis machines)

• Core value: Startup within ≤15 seconds after power failure, ensuring continuous operation of life support equipment and preventing medical accidents; Meet the emergency power supply requirements of GB 50333-2013 "Technical Code for Clean Operating Department Buildings in Hospitals".

2. Data and Communication

• Applicable scenarios: Server rooms in data centers, communication base stations, cloud computing centers, and broadcasting and television transmission towers

• Core Value: Zero power-off switching (with ATS automatic transfer switch), preventing data loss and communication interruption, ensuring 7× 24-hour service continuity.

3. Industrial production

• Applicable scenarios: Manufacturing production lines (such as automobiles, electronics, and chemicals), cold storage refrigeration systems, water pumps/fans and other key power equipment

• Core value: Respond to power grid fluctuations or power outages and reduce production interruption losses; It is suitable for heavy-load starting (such as motor loads), and the starting current can reach three times the rated current.

4. Municipal and public facilities

• Applicable scenarios: Urban sewage treatment plants, water supply booster stations, emergency lighting for subways and airports, traffic signal lights

• Core value: Adapt to harsh outdoor environments (high temperature, low temperature, dust), ensuring the continuity of urban basic functions; It complies with the safety acceptance standards for municipal engineering.

Emergency Diesel Generator Set

5. Commercial and civilian

• Applicable scenarios: Large shopping malls, hotels, office buildings, high-end community elevators/water supply systems, temporary events (exhibitions, competitions)

• Core value: Low noise operation (≤75dB@10 meters), avoiding disturbance to residents; The operation status can be remotely monitored, reducing the cost of manual duty.

Product Advantages (Core Competitiveness of Kecheng Electric Power)

Advantage Category Kecheng Product Features Industry Comparative Advantage
Emergency Response Speed Standard dual-battery starting system, starting success rate ≥99.5%, start time ≤15 seconds. 30% faster start-up than standard units; starts normally at -30°C.
Operational Stability Electronic-controlled high-pressure common rail technology; speed stability ≤±0.2%; voltage regulation ≤±1%. MTBF ≥10,000 hours, 20% higher than industry average.
Customization Capability Supports full power range customization (20-2000kW); can integrate ATS, waste heat recovery, remote monitoring modules. Small power models customized within 15 days; large power models delivered within 30 days.
Energy Saving & Environmental Protection Complies with China IV emission standards; fuel consumption as low as 205 g/(kW·h) (full load). 8% lower fuel consumption than China III models; NOx emissions reduced by 50%.
After-sales Service 30+ nationwide service points; 2-hour response time; 24-hour on-site repair. Core components warranty 2 years; lifetime free technical consultation.

Technical parameters (Mainstream models of Kecheng Electric Power)

Parameter Category 20-100kW (Small Emergency) 100-500kW (Medium Emergency) 500-2000kW (Large Emergency)
Rated Power (Prime/Standby) 20/22kW - 100/110kW 100/110kW - 500/550kW 500/550kW - 2000/2200kW
Rated Voltage / Frequency 220V (Single-phase) / 380V (Three-phase), 50Hz 380V/400V (Three-phase), 50Hz (60Hz optional) 380V/660V/10kV (optional), 50Hz
Power Factor 0.8 (Lagging) 0.8 (Lagging) 0.8 (Lagging), customizable to 0.9 (Leading/Lagging)
Fuel Consumption (Full Load) 210-220 g/(kW·h) 205-215 g/(kW·h) 200-210 g/(kW·h)
Starting Method 12V Electric Start (Dual Battery) 24V Electric Start (Dual Battery) 24V Electric Start + Air Start (Backup)
Cooling Method Forced Air Cooling (20-50kW) / Forced Water Cooling (50-100kW) Forced Water Cooling (with Coolant Heater) Forced Water Cooling (Dual-Circuit Cooling System)
Emission Standard China IV China IV China IV (upgradable to China V)
Unit Dimensions (L × W × H) 1800×800×1200 - 2500×1100×1500 mm 2800×1300×1800 - 4500×1800×2200 mm 5000×2200×2800 - 8000×3000×3500 mm
Unit Weight 800-1500 kg 2000-5000 kg 8000-25000 kg
Noise Level (@10m) ≤70 dB ≤75 dB ≤80 dB (with soundproof canopy)

Technical features (Patented technology of Kecheng Electric Power)

1. Intelligent emergency control system

• Equipped with the KCPLC-01 controller independently developed by Kecheng, it supports "automatic/manual/remote" three-mode control and can be linked with the ATS automatic transfer switch to achieve automatic start when power is off and automatic stop when power is restored.

• It can monitor over 20 operating parameters in real time (such as rotational speed, oil pressure, water temperature, voltage, current, etc.), automatically alarm and record in case of faults (storing 100 fault codes), and supports remote monitoring via mobile phone APP (viewing parameters, start-stop control).


2. High-efficiency power system

• It is compatible with Yuchai YC, Weichai WP and Cummins QSK series engines. It adopts high-pressure common rail + turbocharging technology, which increases combustion efficiency by 12%. When starting at low temperatures, the fuel is heated through the preheating plug, and it can start normally in an environment of -30℃.

• The generator adopts brushless self-excitation technology, with a voltage establishment time of ≤0.5 seconds and strong resistance to load shock (capable of withstanding a sudden increase of 100% of the rated load).


3. Strengthen protection and noise reduction design

• The outer cover of the unit is made of double-layer cold-rolled steel plate (inner layer of sound-absorbing cotton + outer layer of anti-rust coating), with a noise reduction of up to 25dB, meeting the noise requirements of commercial and civil areas.

• The electrical system has a protection grade of IP24 and can withstand light rain and dust. The fuel tank adopts a leak-proof design and complies with GB 18296-2019 "Safety Performance Requirements and Test Methods for Automotive Fuel Tanks".


4. Redundant design for emergency support

• Dual-battery starting system (serving as backups for each other) to prevent starting failure caused by a single battery being discharged.

• The fuel tank capacity supports full-load operation for 8 to 24 hours and can be connected to a large-capacity fuel tank for long-term emergency power supply.

• The key components (such as oil pumps and water pumps) adopt redundant design. When a single component fails, the backup component will be automatically put into operation.

Usage Method (Kecheng Electric Power Standard Operating Procedure)

1.Pre-startup inspection (Mandatory before emergency startup)

Inspection Item Inspection Content Qualification Standard
Fuel System Fuel tank level, fuel line leakage, fuel filter Level ≥ 1/2 tank capacity; lines leak-free; filter not clogged
Lubrication System Engine oil level, oil viscosity Level between MAX-MIN on dipstick; use 15W-40 oil in winter, 20W-50 in summer
Cooling System Coolant level, coolant temperature (low temp environment) Coolant at fill line; coolant temp ≥5°C when below -10°C (via preheater)
Electrical System Battery voltage, ATS switch status, controller fault alarm 12V models ≥12.5V; 24V models ≥25V; ATS set to "Auto"; no fault alarms

2. Emergency start-up operation (automatic mode, recommended)

1. Switch the controller knob to the "Auto" mode, and the ATS will automatically monitor the grid voltage.

2. When the power grid is cut off, the ATS triggers the start-up signal of the unit, and the unit starts automatically (start-up time ≤15 seconds).

3. After startup, the controller monitors the rotational speed (up to 1500r/min), oil pressure (≥0.3MPa), and water temperature (gradually rising to 70℃). Once the parameters stabilize, the ATS automatically switches the load to supply power to the unit.


3. Manual start operation (emergency backup)

1. Switch the controller to "manual" mode and press the "Preheat" button (preheat for 30-60 seconds in low-temperature environments);

2. Press the "Start" button. After the unit starts, observe the parameters. Once they stabilize, manually close the output switch and then switch the load through ATS.

3. When the load is put into operation, it should be gradually loaded. The initial loading should not exceed 50% of the rated power. After 5 minutes, it can be raised to full load.


4. Shutdown operation (after power grid restoration)

1. After the power grid resumes power supply, the ATS automatically disconnects the load of the unit and switches to power supply from the grid.

2. When the unit enters no-load operation (for 3 to 5 minutes to cool down the engine), the controller automatically shuts down (or manually press the "Stop" button).

3. After the machine stops (for long-term shutdown), close the fuel valve, check for any leakage or component damage in the unit, and record the operating data.

Precautions (safety and maintenance)

1. Safety Protection (Red Line Clause)

1. The installation area of the unit should be far away from open flames, flammable and explosive items, and have good ventilation (the ventilation volume per hour should be ≥ 15 times the volume of the unit).

2. Operators must be professionally trained by Kecheng Electric Power and hold relevant certificates before taking up their posts. It is strictly prohibited to disassemble fuel pipelines and electrical components when the unit is in operation.

When starting up in an emergency, it is necessary to confirm that there is no short circuit at the load end to avoid equipment damage caused by starting the unit under load.

3.Regularly check whether the gas leakage alarm (if any) and fire extinguisher are functioning properly to ensure they can be used in emergency situations.

2.Maintenance Cycle (Recommended by Kecheng Electric Power)

Maintenance Cycle Maintenance Content Precautions
Daily (Standby Emergency) Check fuel level, battery voltage, controller status. For long-term standby, start unit and run unloaded for 15 minutes weekly to prevent part corrosion.
50 Hours (First Maintenance) Change engine oil, replace oil filter. Use only specified Kecheng oil brands (e.g., Great Wall Zunlong T500).
200 Hours Replace fuel filter, replace air filter. Clean cooling system radiator dust; check drive belt tension.
500 Hours Check valve clearance, injector pressure; calibrate controller parameters. Large units require checking excitation system brush wear.
2000 Hours Full disassembly inspection of engine and generator; replace seals. Must be performed on-site by a Kecheng Power service engineer.

3.Environmental adaptation measures

• High-temperature environment (≥40℃) : Install cooling fans and sunshades, and check the coolant temperature every 2 hours (≤95℃).

• Low-temperature environment (≤-10℃) : Replace low-temperature engine oil and antifreeze (concentration ≥50%), and activate the fuel preheater and engine oil preheater.

• High-altitude environment (≥1000 meters) : The engine needs to be modified for high altitudes (increasing the intake air volume), with power correction factors of 0.95 (1000-2000 meters) and 0.9 (2000-3000 meters).

4.Common Fault Handling (Quick Troubleshooting by Kecheng Electric Power)

Fault Symptom Possible Causes Solution
Emergency Start Failure Battery drained, fuel line clogged, preheater malfunction Charge or replace battery; clean fuel line; check preheater fuse
Voltage Fluctuation Generator excitation system fault, excessive load fluctuation Check excitation brushes (for brushed models); control load change amplitude (≤50%)
Abnormally High Fuel Consumption Injector wear, incorrect oil viscosity, air filter clogged Replace injector; use appropriate oil; clean/replace air filter
Excessive Unit Vibration Anchor bolts loose, uneven drive belt tension Tighten anchor bolts; adjust belt tension (deflection ≤10mm when pressed)