Imported Diesel Generator Set
  • Imported Diesel Generator SetImported Diesel Generator Set

Imported Diesel Generator Set

The imported diesel generator sets supplied by Kecheng from China are worth considering if you need to purchase quality imported power generation equipment for high-end medical, data center or multinational industrial projects,. The core of this unit is made of international first-line components, which comply with European, American and international standards and certifications. It meets the backup and main power supply requirements of high-demand places such as medical institutions and data centers, and provides localized service guarantees.

The imported diesel generator sets of Kecheng are reliable made-in-China products that you can trust. The core components of the unit, such as the engine and generator, are all from internationally renowned brands, ensuring the reliability of power and power generation, and have passed international certifications such as CE and EPA. The product is equipped with an independently developed intelligent control system, which is compatible with various usage environments. At the same time, it supports localized installation and maintenance services, eliminating concerns about the inconvenience of after-sales service for imported equipment. The core components are covered by a 2-year or 10,000-hour warranty service. The greater the power, the more comprehensive the guarantee. Whether it is a data center that requires continuous and stable power supply or a medical institution with strict requirements for power quality, this imported unit can provide reliable power support that meets international standards.


This equipment covers the full power range of small and medium-sized (20-200KW), medium and large (200-800KW), and large (800-2000KW).

Power Class Engine Models (Imported) Generator Models (Imported) Main Features Target Applications
20-200KW (Small/Medium) Cummins QSF series (USA), Perkins 4000 series (UK) Stamford P50 series Portable & Efficient Small/medium high-end commercial scenarios
200-800KW (Medium/Large) Cummins QSX series (USA), Volvo TAD series (Sweden) Marathon MP series Stable & Long-lasting Medium/large public facilities and industrial needs
800-2000KW (Large) Cummins QSK series (USA), MAN D28 series (Germany) Stamford HC series High Voltage (6kV/10kV) Industrial Heavy-duty Large multinational factories and energy bases

Application scenarios (Exclusive adaptation for high-end scenarios)

Imported Diesel Generator Set

1. High-end medical and life science scenarios (20-200KW/200-800KW)

• Applicable scenarios: ICU/operating rooms in tertiary hospitals (ventilators, dialysis machines), biopharmaceutical factories (fermentation equipment in aseptic workshops), genetic testing laboratories (precision analytical instruments)

• Core value: The imported engine has an MTBF (Mean Time Between Failures) of no less than 15,000 hours, and can start within no more than 10 seconds after power failure, meeting the power supply requirements for medical "first-class loads". The voltage distortion rate of the generator is ≤2% to prevent voltage fluctuations from affecting precision instruments (such as gene sequencers). It complies with GMP certification in the medical industry and CE electromagnetic compatibility standards for medical devices, and has no electromagnetic interference.


2. Cross-border industrial and high-end manufacturing scenarios (200-800KW/800-2000KW)

• Applicable scenarios: Automotive joint venture factories (welding robots, painting production lines), semiconductor wafer fabrication plants (cleanroom air conditioning, auxiliary equipment for photolithography machines), aviation parts manufacturing plants (high-precision processing machine tools)

• Core value: Imported engines can withstand "24-hour full-load operation" (annual operating time ≥ 8,000 hours), making them suitable for continuous industrial production. Supports parallel connection of multiple units (such as two 1000KW units linked together), with a load balancing deviation of no more than 3%. It complies with the EU CE and US EPA Tier 4 Final emission standards and meets the global environmental protection compliance requirements of multinational enterprises.


3. Super-large data centers and financial scenarios (800-2000KW)

• Applicable scenarios: Cross-border cloud computing centers (backup power supply for server clusters, 10kV high-voltage output), head office data centers of banks (emergency power supply for core trading systems), stock exchanges (guarantee for market information systems and trading terminals)

• Core value: Imported high-voltage generator (6kV/10kV) with insulation class H, short-circuit withstand time ≥3 seconds, directly connected to the high-voltage power distribution system of the data center; The intelligent control system supports linkage with the DCIM system of the data center to achieve "on-demand load adjustment + remote operation and maintenance". The annual downtime due to faults is no more than 1 hour, ensuring zero interruption of financial transactions.

Imported Diesel Generator Set


4. High-end commercial and foreign-related scenarios (20-200KW/200-800KW)

• Applicable scenarios: International five-star hotels (power supply for presidential suites, equipment for international conference centers), headquarters of foreign-funded enterprises (emergency power supply for office buildings, video conferencing systems), international airport VIP lounges (high-end service facilities)

• Core value: The operating noise of imported engines is ≤70dB@10 meters (for medium and small-sized models), and when paired with the custom silent cover from Kecheng, it can be reduced to 65dB, meeting the high-end commercial noise standards. The fuel consumption rate is as low as 195g/(kW · h) for medium and large-sized models, and the long-term operating cost is controllable. Supports multi-language controllers (Chinese/English/German/French), adapting to the operation requirements of foreign-related scenarios.


5. Overseas Infrastructure and Energy Scenarios (Full Power Segment)

• Applicable scenarios: African mines (underground ventilators, mining equipment, explosion-proof type), Southeast Asian island resorts (independent power grid supply), Middle East oil-producing areas (auxiliary power supply for drilling platforms, high-temperature type)

• Core value: The imported engine is adapted to extreme environments (-35℃ to 55℃ high/low temperature, high dust/high humidity). The African model can be optionally equipped with an explosion-proof version (Ex dⅡB T4), and the Middle East model is equipped with a high-temperature cooling kit. In line with the certifications of the target countries (such as SONCAP in Africa and TISI in Southeast Asia), Kecheng provides overseas installation guidance and spare parts supply to solve cross-border after-sales problems.

Product advantages (Core competitiveness of imports)

Advantage Category 20-200KW (Small/Medium) 200-800KW (Medium/Large) 800-2000KW (Large)
International Quality Assurance Imported Cummins QSF/Perkins 4000 engines, factory QC, failure rate ≤0.5%/year. Imported Cummins QSX/Volvo TAD engines, reinforced pistons & crankshaft, withstands 24h full load. Imported Cummins QSK/MAN D28 heavy-duty engines, bore diameter ≥150mm, suitable for industrial heavy loads.
Global Compliance Complies with CE, EPA Tier 4, ISO 8528; exportable to EU/US. Additionally certified with UL (USA), CSA (Canada), adaptable to North American market. Complies with IEC (International Electrotechnical Commission) HV standards, supports global grid connection (50/60Hz).
Power Performance Starting success rate ≥99.8% (-30°C), fuel consumption 205-220 g/(kW·h). Low-speed torque ≥1200 N·m (1500 rpm), fuel consumption 195-205 g/(kW·h). Cylinder block temperature ≤90°C at rated power, fuel consumption 190-200 g/(kW·h), withstands 3x rated current impact load.
Intelligent O&M Kecheng KCPLC-06 imported dedicated controller, bilingual (EN/CN), basic remote monitoring. Adds peak/off-peak power management, multi-unit parallel control; one person manages 5-8 units; fault warning accuracy ≥98%. HV monitoring module (6kV/10kV), integrates with industrial DCS; 100% remote diagnostic coverage.
After-sales Support Imported engine original warranty: 2 years / 10,000 hours; Kecheng 30+ localized service points. Dual after-sales (OEM + Kecheng), response within 4h, on-site repair within 24h. Dedicated service engineers (OEM certified); core parts in stock; repair cycle ≤24h.

Technical parameters (Full power range: 20-2000KW)

Parameter Category 20-200KW (Small/Medium) 200-800KW (Medium/Large) 800-2000KW (Large)
Rated Power (Prime/Standby) 20/22 - 200/220 KW 200/220 - 800/880 KW 800/880 - 2000/2200 KW
Imported Engine Brand/Model Cummins QSF2.8/QSF6.8, Perkins 404D-22/4012-46TWG2A Cummins QSX15, Volvo TAD1375VE, Perkins 4016-61TRG3 Cummins QSK19/QSK60, MAN D2876LE203, Volvo TAD1643VE
Imported Generator Brand/Model Stamford P50, Marathon LVS series Stamford HCI, Marathon MP series Stamford HC, Marathon MG series (High Voltage 6kV/10kV)
Rated Voltage / Frequency 380V/660V, 50/60Hz (switchable) 380V/660V/6kV, 50/60Hz 6kV/10kV, 50/60Hz (customizable)
Power Factor 0.8 (Lagging), customizable to 0.9 (Lagging) 0.8 (Lagging) 0.8 (Lagging), customizable to 0.9 (Leading/Lagging)
Full Load Fuel Consumption 205-220 g/(kW·h) 195-205 g/(kW·h) 190-200 g/(kW·h)
Starting Method 24V Electric Start (Dual Battery, Imported Starter) 24V Electric Start + Air Start (Dual Backup, Imported Components) 24V Electric Start + Air Start + Hydraulic Start (Triple Backup)
Cooling Method Forced Air Cooling (20-50KW) / Forced Water Cooling (50-200KW) Forced Water Cooling + Temperature-Controlled Fan (Imported Pump/Fan) Forced Water Cooling + Independent Cooling Tower (Imported Thermostatic Valve)
Protection Rating IP24 (Standard) / IP54 (Rainproof) IP24 / IP54; Explosion-proof IP65 (Ex dⅡB T4) IP54 / IP65 (High Voltage); Explosion-proof Ex dⅡB T4
Operating Noise (@10m) 70-75dB (Standard) / 65-70dB (Silenced) 72-77dB (Standard) / 68-72dB (Silenced) 75-80dB (Standard) / 70-75dB (Silenced)
Unit Dimensions (L×W×H) 2200×1000×1400 - 3800×1500×1900 mm 4000×1800×2100 - 6000×2200×2600 mm 6500×2800×3200 - 10000×3500×4000 mm (Containerized)
Unit Weight 800-3500 kg 3500-8000 kg 8000-32000 kg
Warranty Period Engine/Generator: 2 Years / 10000 Hours Engine/Generator: 2 Years / 12000 Hours Engine/Generator: 2 Years / 15000 Hours

Technical features (Exclusive design for imported components)

1. Core technology of imported engines

• Small and medium-sized (20-200KW) : The Cummins QSF series adopts the "high-pressure common rail (2000bar) + turbocharged intercooling" technology, which increases combustion efficiency by 15%. When starting at low temperatures, it can be started through the intake preheating plug (-30℃ can be started). The Perkins 4000 series is equipped with an electronic speed controller, with a stable speed accuracy of ≤±0.2%, making it suitable for civilian precision equipment.

• Medium and large-sized (200-800KW) : Cummins QSX series with variable geometry turbocharger (VGT), the boost pressure increases by 30% at low speeds, and the torque response time is ≤0.5 seconds. The Volvo TAD series adopts double overhead camshafts (DOHC), providing more precise valve control and extending the oil change cycle to 1,000 hours.

• Large (800-2000KW) : The Cummins QSK series features a V-type 12/16 cylinder structure. The cylinder block is made of vermicular graphite cast iron (with a strength 70% higher than that of ordinary cast iron), capable of withstands industrial heavy loads. The MAN D28 series is equipped with an exhaust after-treatment system (SCR+DPF), meeting the Euro V/US Tier 4 Final emission standards and adapting to global environmental protection requirements.


2. Technical advantages of imported generators

• Low-voltage models (20-800KW) : The Stanford P50/HC series adopts the "brushless self-excitation + permanent magnet excitation" technology. The voltage establishment time is ≤0.3 seconds, the voltage regulation rate is ≤±0.5%, and it has strong load shock resistance (can withstand 2.5 times the rated current for 10 seconds). The Marathon LVS/MP series has an insulation class of F and a temperature resistance of 155℃, making it suitable for long-term operation.

• High-voltage models (800-2000KW) : The Stanford HC and Marathon MG series are insulated with epoxy glass cloth tubes (resistant to high-voltage breakdown), and the stator windings are shielded with copper (to reduce electromagnetic interference), in compliance with the IEC 60034 high-voltage motor standard. Equipped with imported high-voltage switch cabinets (ABB/Siemens components), featuring overcurrent, grounding and overvoltage protection, it has a high safety level.


3. Kecheng customized Integration technology

• Intelligent Control System (KCPLC-06) : Specifically developed for imported units, it supports: ① Multi-language interface (Chinese/English/German/French/Spanish), suitable for foreign-related scenarios; ② Specialized diagnosis for imported engines (reading engine ECU fault codes, such as Cummins Insite system data); ③ Global remote monitoring (supporting 4G/satellite networking, overseas projects can transmit data in real time);

• Environmental adaptation structure: Small and medium-sized models can be equipped with "trailer-type mobile design" (imported shock absorbers, vibration transmission rate ≤8%), medium and large-sized models can be equipped with "container-type integrated" (with imported temperature control system, operating at -35℃ to 55℃), and large high-voltage models are equipped with "imported high-voltage connectors" (ABB brand, insulation grade 10kV).

• Fuel and lubrication optimization: Adapted to the requirements of imported engines, the fuel system adopts imported filter elements (Parker), with a filtration accuracy of 10μm; The lubrication system uses imported long-lasting engine oil (Mobil 1 / Shell Helix Ultra, with an oil change cycle of 1000 hours) to reduce engine wear.


4. Global compliance and compatibility

• Full coverage of international certifications: The entire series has passed CE (EU Safety), EPA Tier 4 (US Environmental Protection), ISO 8528 (Generator set performance), and UL 2200 (US safety) certifications, and can be exported to major global markets.

• Grid compatibility: Supports 50/60Hz frequency switching (via imported frequency converters), and the voltage can be customized (220V/380V/480V/6kV/10kV), adapting to different national grid standards (such as 480V/60Hz in the United States, 400V/50Hz in Europe);

• Electromagnetic Compatibility (EMC) : Complies with EN 61000-6-2 (Industrial Environment) and EN 61000-6-4 (Civil Environment) standards, free from electromagnetic radiation interference, and suitable for sensitive scenarios such as medical and laboratory Settings.

Power selection (Precise matching for high-end scenarios)

1. core selecting basis

Selection Dimension 20-200KW (Small/Medium) 200-800KW (Medium/Large) 800-2000KW (Large)
Scenario Priority Reliability > Low Noise > Cost; suitable for high-end commercial / small precision applications. Stability > Continuous Operation > Compliance; suitable for medium/large industrial / medical applications. Heavy-Load Tolerance > High-Voltage Compatibility > Global Compliance; suitable for large industrial / energy applications.
Load Characteristics Light/Intermittent loads (e.g., lab instruments, hotel rooms); load factor ≤50%. Medium/Continuous loads (e.g., production lines, hospital ICUs); load factor 50%-80%. Heavy/Full loads (e.g., industrial machinery, data centers); load factor ≥80%.
Compliance Requirements CE/EPA certification required; no high-voltage needs. CE/UL/CSA certification required; low/medium voltage optional. IEC/EN high-voltage standards required; global grid compatibility; explosion-proof / high-temperature needs.
After-sales Needs Localized quick response; easy spare parts availability. Dual after-sales (OEM + Kecheng); long-term maintenance support. Dedicated certified engineers; overseas spare parts supply guaranteed.

2.Power recommendation for typical scenarios

Scenario Type Load Details Recommended Power Range Recommended Configuration
Private High-end Hospital (100 beds) ICU equipment (30kW) + Operating rooms (20kW) + Laboratories (15kW) 80-100KW 100KW Cummins QSF6.8 model, with soundproof enclosure (65dB), CE Medical Certification
Automotive JV Factory (Welding Shop) Welding robots (200kW × 2) + Conveyor lines (100kW) + HVAC (50kW) 600-800KW 800KW Volvo TAD1643VE model, multi-unit parallel (2 x 400KW units), UL Certification
Multinational Data Center (5000 racks) Server clusters (1500kW) + HVAC (800kW) + Lighting (100kW) 2000KW (2 x 1000KW in parallel) 1000KW Cummins QSK60 model, 10kV high-voltage output, IEC Certification
African Mine (Copper Mining Area) Crusher (500kW) + Ventilation fans (200kW) + Drainage pumps (100kW) 800-1000KW 1000KW MAN D2876 model, explosion-proof version (Ex dⅡB T4), SONCAP Certification

Usage Method (Exclusive operation for imported units)

1.Pre-startup inspection (with a focus on imported components)

Power Range Inspection Focus Qualification Standard (Special Requirements for Imported Components)
20-200KW Imported engine oil level (dedicated oil), generator insulation resistance, controller ECU connection Use imported long-life oil (e.g., Mobil 15W-40), oil level between MAX-MIN marks; insulation resistance ≥50 MΩ; ECU shows no fault codes (read via controller).
200-800KW Imported turbocharger status, high-voltage connections (6kV models), air start system pressure Turbocharger shows no oil leakage, impeller rotates freely; HV terminal torque meets import standards (e.g., ABB terminals 35 N·m); air start pressure ≥0.7 MPa.
800-2000KW Imported high-voltage switchgear status, hydraulic start oil level, engine ECU parameters HV switchgear in "open" position, insulation monitoring normal; hydraulic oil level ≥ 2/3 of tank capacity; ECU displays normal water temp/oil pressure (no alarms).

2. Startup operation (power distribution process)

(1) 20-200KW (starting with imported engine)

1.ECU self-check: Turn on the controller power and wait for the imported engine ECU to self-check (about 30 seconds). Confirm that there are no fault codes (such as the Cummins "STOP" light not on).

2. Preheating start: Press the "Preheating" button (preheat for 60 seconds in a low-temperature environment, with the inlet preheating plug working), then press the "Start" button. After the engine starts, observe the rotational speed (1500r/min±50r/min) and oil pressure (≥0.3MPa).

3. Loading operation: After the parameters stabilize (about 5 minutes), close the generator output switch and gradually load (the initial load should be ≤50%, and after running for 10 minutes, increase to full load to avoid impacting the inlet generator).

(2) 800-2000KW (High voltage/heavy-duty imported units)

1. High-voltage preparation: Open the "grounding switch" of the imported high-voltage switch cabinet → Close the "disconnector" → Use an imported voltage detector (such as ABB) to confirm that there is no electricity.

2. Startup process: Hydraulic start → Engine speed rises to 1500r/min→ Check the pressure of the imported turbocharger (≥0.2MPa) → Close the high-voltage circuit breaker → Load in stages of "20%→50%→80%→100%".

3.ECU Monitoring: The controller reads the engine ECU data (water temperature, oil temperature, fuel injection pressure) in real time. When the threshold is exceeded, the load is automatically reduced to prevent damage to imported components.


3. Operation Monitoring and Shutdown (Protection of Imported Components)

• Key monitoring points: For 20-200KW, pay attention to the ECU parameters of imported engines (no abnormal codes); for 800-2000KW, focus on high-voltage parameters (voltage 6kV±5%) and the temperature of imported turbochargers (≤600℃).

• Shutdown process:

① 20-200KW: Unload → turn off the output switch → Run no-load for 5 minutes → Shut down → turn off the power of the ECU.

② 800-2000KW: Graded unloading → Disconnect the high-voltage circuit breaker → Open the "disconnector" → close the "grounding switch" → Run no-load for 10 minutes → shut down → Record the ECU operation data (for after-sales analysis).

Safety and Protection (Compliance Specifications for Imported Units)

1. Safe installation (in line with international standards)

• Site selection and layout:

① The installation area should be at least 15 meters away from open flames (the exhaust temperature of imported engines is high, so avoid ignition). For high-pressure models, the safety distance should be at least 3 meters (in compliance with IEC 61936 high-pressure standards).

② The ground load-bearing capacity should be no less than 1.5 times the weight of the unit (for large models, it should be no less than 32000kg×1.5=48000kg/㎡). The foundation should be made of reinforced concrete (with a thickness of no less than 500mm), and equipped with imported shock-absorbing pads (such as Kordon).

③ Overseas projects must comply with local building codes (such as NFPA 110 in the United States and EN 50130-7 in Europe), and Kecheng provides local installation drawing certification.

• Electrical safety:

① The grounding resistance of the imported high-voltage generator is ≤10Ω (conforming to IEC 60364), and that of the low-voltage model is ≤4Ω. The grounding electrode uses imported galvanized flat steel (such as British standard BS EN 10025).

② Imported insulating gloves for high-voltage wiring (with a withstand voltage of 10kV, such as Sperian), and two people should cooperate during operation (one person operating and one person supervising).

③ Imported electrical components (such as circuit breakers and contactors) must be wired in accordance with the original factory specifications. Unauthorized modification is strictly prohibited (to avoid losing the original factory warranty).

• Fire protection configuration:

① The installation area is equipped with imported dry powder fire extinguishers (such as Ansul, ABC type 8kg), and high-pressure models are additionally equipped with CO₂ fire extinguishers (to prevent electric shock).

② The fuel tank is independently set up (at least 10 meters away from the unit), using imported explosion-proof pipe fittings (such as Parker), and complies with the NFPA 30 fuel storage standard.

③ Overseas projects must pass local fire protection acceptance (such as FM certification in the United States and CE fire protection certification in Europe).


2. Operational safety (Exclusive for imported components)

• Personnel requirements:

①Operators must undergo dual training from "imported brands + Kecheng" (such as training authorized by Cummins), and after passing the assessment, they can work with the "Imported Unit Operation Certificate".

② Be familiar with the meaning of ECU fault codes for imported engines (for example, Cummins' "code 128" indicates low oil pressure), and be able to quickly identify basic faults.

③ When operating, wear imported protective equipment (insulating shoes, high-temperature resistant gloves, such as Dupont), and avoid contact with high-temperature components (the temperature of imported turbochargers ≥600℃).

• Operating contraindications:

① Do not use non-imported specified engine oil/filter elements (for example, Cummins requires CJ-4 grade engine oil), otherwise the original factory warranty will be lost.

② It is strictly prohibited to disconnect the imported high-voltage circuit breaker under load (to avoid arc burns, it needs to be unloaded first).

③ Do not force the operation when the ECU alarms (for example, when the "high water temperature" alarm is triggered, the machine should be stopped immediately to prevent the imported engine from pulling the cylinder).

• Emergency response:

① Imported engine failure: Stop immediately → Read the ECU fault code → Contact Kecheng after-sales service (provide the fault code for remote diagnosis by the original factory);

② High-voltage leakage: Disconnect the upper-level power supply → Wear imported insulating equipment → Isolate the fault point with imported insulating rods → Check the wiring.

③ Fire accident: Use imported fire extinguishers to put out the fire → Call the local fire department → Contact the after-sales service of the imported brand to assess the damage to the components.


3. Maintain safety (Specifications for Imported components)

• Preparations before maintenance:

① Disconnect the power supply of the unit, close the fuel valve, hang the warning sign "Under maintenance, do not start", and for high-voltage models, ground discharge is required.

② Prepare imported special tools (such as Cummins special wrenches, Volvo diagnostic instruments), and the spare parts must be genuine products from the original factory (Kecheng provides the import spare parts channel).

③ The maintenance manual should refer to the specifications of the imported brand (such as the maintenance manual of MAN D28), and simplifying the process is strictly prohibited.

• Maintenance operations:

① Oil/filter replacement: Replace the oil with an imported oil pump (such as Black & Decker) in accordance with the required cycle of the imported engine (e.g., 1000 hours for Cummins), and hand over the old oil to a qualified institution for disposal.

② Maintenance of imported generators: Test the insulation resistance with imported insulating oil (≥100MΩ) every six months, and clean the imported bearings (add imported grease, such as Shell Gadus).

③ High-voltage system maintenance: Every year, relay protection (such as ABB protection devices) is calibrated by certified engineers of imported brands and short-circuit withstand capability is tested.

Maintenance and Servicing Schedule (Exclusive for Imported sets)

Maintenance Level 20-200KW (Small/Medium) 200-800KW (Medium/Large) 800-2000KW (Large) Responsible Party
Daily Daily: Check ECU fault codes, oil level, fuel level. Daily: Monitor ECU parameters, HV insulation, air start pressure. Daily: Record ECU data, check HV switchgear status, check hydraulic oil level. User O&M Team (Trained)
Weekly Weekly: Clean air filter, check imported battery voltage. Weekly: Clean air filter, visual inspection of imported turbocharger. Weekly: Check air/fuel filter, check imported cooling fan status. User O&M Team
Monthly Monthly: Replace fuel filter (Parker imported element), calibrate controller. Monthly: Replace fuel/oil filter (imported spare parts), test generator insulation. Monthly: Replace fuel/oil filter, check imported hydraulic system oil level. Kecheng Service + User Team
Quarterly Every 3 Months: Download imported engine ECU data, check soundproof enclosure. Every 3 Months: Check engine valve clearance (imported tools), calibrate parallel parameters. Every 3 Months: Perform engine cylinder pressure test, HV insulation test (imported instruments). Kecheng Service Engineer (Imported Brand Certified)
Annual Yearly: Perform imported engine deep inspection, replace generator bearings. Yearly: Maintain engine turbocharger, calibrate HV relay protection. Yearly: Inspect engine pistons/crankshaft, inspect imported HV components. Imported Brand + Kecheng Joint Service
Long-term Storage Idle ≥1 Month Treat imported engine with anti-rust spray, drain fuel, charge battery. Same as left, plus add insulation protection for HV switchgear (imported insulating cover). User O&M Team